Current Carrying Capacities
| Nominal Size |
Nominal Diameter |
Max.Dia. |
Area |
Current Carrying Capacities (A) |
| (mm) |
(mm) |
(cm2) |
RP |
UHP |
UHP for DCF |
| 14T |
350 |
357 |
999 |
16,000~24,000 |
22,000~39,000 |
- |
| 16T |
400 |
408 |
1,305 |
21,000~30,000 |
28,000~47,000 |
- |
| 18T |
450 |
459 |
1,652 |
- |
34,000~55,000 |
- |
| 20T |
500 |
510 |
2,040 |
- |
41,000~63,000 |
- |
| 22T |
550 |
561 |
2,469 |
- |
48,000~70,000 |
65,000~78,000 |
| 24T |
600 |
612 |
2,939 |
- |
55,000~82,000 |
75,000~90,000 |
| 26T |
650 |
663 |
3,449 |
- |
69,000~89,000 |
87,000~104,000 |
| 28T |
700 |
714 |
4,001 |
- |
80,000~100,000 |
100,000~120,000 |
| 30T |
750 |
765 |
4,593 |
- |
- |
110,000~132,000 |
| 32T |
800 |
816 |
5,226 |
- |
- |
122,000~146,000 |
| Nominal Size |
Current Densities (A/cm2) |
| RP |
UHP |
UHP for DCF |
| 14T |
16~24 |
22~39 |
- |
| 16T |
16~23 |
21~36 |
- |
| 18T |
- |
21~33 |
- |
| 20T |
- |
20~31 |
- |
| 22T |
- |
19~28 |
26~32 |
| 24T |
- |
19~28 |
26~31 |
| 26T |
- |
20~26 |
25~30 |
| 28T |
- |
20~25 |
25~30 |
| 30T |
- |
- |
24~29 |
| 32T |
- |
- |
23~28 |
Note:Current capacities listed above are typical values for typical electrodes.
In case using the electrode beyond the above values, please consult Tokai Carbon or our overseas agents.